Add to Cart
Fiberglass Screw Compressor Air Oil Separator 92890334
Screw air compressor oil separator:
Screw air compressor oil and gas separator filter is normal work, affect the air compressor system output is pure available.Air compressor in the use of the process to replace the oil separator in time, a general time for 3000- 5000 hours, this should be adjusted according to the merits of the use environment.
1.Clogged oil separator will lead to poor separation efficiency of oil and gas separator filter element.
2.Increased oil consumption and heavy oil content in compressed air affect the operation of back-end purification equipment and the normal operation of gas equipment.
3.The pressure resistance increases after oil blockage, resulting in the increase of actual exhaust pressure and energy consumption of the unit.
Model | Flow m3/min/0.7Mpa | Original air filter element number | Filter element diameter mm | Filter element height mm |
VHP400SCU | 11.6 | 92686948 | 242 | 484 |
92686955 | 127 | 476 | ||
EP200 | 20 | 99266702 | 270 | 370 |
M90 | 20 | 39903281 | 380 | 178 |
150S | 20 | 39903281 | 380 | 178 |
VHP700E | 20 | 92035948 | 300 | 460 |
P1050E | 29.5 | 92035955 | 150 | 468 |
P600SCU | 17 | 92686922 | 225 | 372 |
92686930 | 109 | 376 | ||
M250 | 40 | 42852129 | 380 | 362 |
39903265 | ||||
900 | 89288971 | 295 | 583 | |
89288969 | 192 | 573 |
There are several ways of judging:
Due to the oil and gas separator filter plug caused by the consequences we can not take lightly, the problem will cause more impact if not dealt with in a timely manner, in order to avoid In this case, we need to timely determine whether the air pressure oil separator core is blocked.Then how to judge whether the oil and gas separator is blocked?
1.If the separator is damaged or ruptured, the oil content in the compressed air will increase and the lubricating oil replenishment period will be shortened. In severe cases, all the lubricating oil will be taken away by the compressed air.
2. When blocking the oil and gas separator, the motor load will increase, the current will increase, and the oil pressure will increase.In severe cases, the motor thermal relay will protect the motor.
3.When the pressure difference of the oil-air separator pressure difference switch exceeds the set value 0.1 1MPa, the pressure difference switch will act, or when the internal set time is zero, controlthe panel shows that the oil and gas separator is clogged, which means that the oil and gas powder separator is clogged and should be replaced immediately. When the oil and gas separator is blocked, all of the above phenomena may occur. When any one of the phenomena occurs, analysis and judgment should be made based on the daily maintenance and repair records of the screw air compressor, and the problematic oil separator should be replaced in time to avoid Cause a greater impact.